1747-ACN15
and 1747-ACNR15
ControlNet
Adapters for 1746 I/O
General enquiries / Order
requests
The
new 1747-ACN15 and 1747-ACNR15 (SLC ACN) ControlNet™
I/O adapters bring the features and performance of ControlNet
phase 1.5 to 1746 I/O. These adapter
modules provide the capability for up to three 1746 chassis
(30 slots) of discrete, analog and specialty I/O modules to produce/consume
scheduled I/O to a ControlNet network. SLC ACN
adapter modules have been designed to provide both scheduled
and unscheduled ControlNet network connections for 1746
I/O. SLC ACN adapter modules are connected
to the ControlNet network via standard BNC
connectors (redundant connection available
in the 1747-ACNR). The modules are powered from and communicate
with I/O modules over the SLC chassis back plane. The
SLC ACN adapter communicates with ControlNet controllers (e.g.
PLC-5C, 1747-SCNR, 1784-KTCS, etc.) via the network. The
two new adapters are configured on the ControlNet network with
RSNetworx release 2.0.
1747-ACN
& 1747-ACNR Features:
-
4
digit/7-segment display for node address and module status
-
Node
address set via rotary switches (in decimal)
-
No
DIP switches needed for module configuration
-
Optional
media redundancy (dual BNC connectors) available with ACNR
-
Compatible
with all 1746 discrete, analog, and specialty modules except
modules
requiring G file configuration, e.g. 1747-SN
-
Capable
of communicating with up to 3 chassis (30 slots) of 1746 I/O
per node
-
Supports
multiple connections to individual modules or rack connections
to a group of discrete modules.
-
Software
upgradable via Flash
-
Up
to 64 connections per adapter are possible with 255 words (max)
per connection
-
Supports
ControlNet scheduled and unscheduled messaging
-
UL/CUL/CE/Class
1, Division 2 certified
|
|