Fluke 744
Documenting Process Calibrators


General enquiries / Order requests

The Fluke 744 offers all of the capabilities of the 7433, plus the ability to calibrate, maintain, and troubleshoot HART instrumentation with just one tool. This rugged, reliable tool offers:


  • Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ins.
  • NIMH battery with 3500 mA hour life and gas gauge.


The 744 offers the most complete HART implementation of any process calibrator. The 744:

  • Requires no external box or second tool for everyday HART calibration and maintenance.
  • Offers fast HART communication.
  • Supports popular models of HART transmitters, with more device-specific command support than any other HART field calibrator.
  • Fully complies with the Data Link Layer of the HART protocol, supporting multiple masters, burst mode, and multi-drop configurations.
  • Is easy to update as additional instruments and new HART versions are released.
  • Is based on the 7433, the most rugged, reliable multifunction field calibrator available.
  • Is backed by the service and support of the Fluke organization, a member of the HART Communications Foundation.


With one powerful tool, you can:


  • Generate precision electrical, temperature, or pressure signals for analog stimulus or sensor simulation.
  • Simultaneously measure electrical, temperature, or pressure signals from transmitter output.
  • Interrogate HART devices to determine type, manufacturer, model, and tag-ID.
  • Read HART PV function, smart transmitter digital output, while measuring analog mA output.
  • Make field adjustments to ranging, damping, and other top-level configuration settings by reading and writing HART configuration functions.
  • Re-label smart transmitters by reading and writing HART tag and message fields.
  • Clone additional transmitters by reading and storing basic HART configurations.
  • Perform automated HART sensor trim and output trim for selected devices.
  • Perform loop test with simultaneous analog and digital mA readout.
  • Address new, fast, pulsed-excitation smart transmitters and PLCs.