Telephone Line |
|
|
Maximum data rate |
33.6 kbps (V.34) |
|
Compatibility |
V.34, V.32 bis, V.32, V.23,V.22, V.22 A/B, V.21, Bell 212A and 103 |
|
Data compression |
V.42 bis MNP 5 |
|
Error correction |
V.42 MNP 2 - 4 |
|
Max. fax modem rate |
14.4 kbps |
|
Fax modem capabilities |
Group 3 (V.33, V.17, V.29, V.27 ter, V.21 channel 2) |
|
Ringer Jack |
0.3 |
|
Line jack |
RJ11 |
|
Auxiliary phone jack |
RJ11 |
|
PLC Discrete I/O Interface |
|
|
"Trigger" Input |
Connects to PLC output. Starts auto-dialing upon transition from OFF to ON. Modem will stay connected while input is ON. |
|
Voltage Range |
9 to 30 VDC |
|
Input Current |
6.5 mA at 24 VDC |
|
Max. OFF Voltage |
5 VDC |
|
"On-Line" Output |
Output is ON as long as a connection exists (carrier detect) |
|
Output Characteristics |
Sourcing - switches supply power |
|
Max. output current |
100 mA |
|
RS232 Port |
|
|
Max. RS232 Rate |
115.2 kbps (kilobaud) |
|
RS232 Signal Support |
TXD, RXD, CTS, RTS, DCD, DTR, DSR, RI, GND |
|
RS232 Connector |
DB9 female |
|
Command Set |
All standard AT and S register commands, incl. Class 1 & 2 Fax |
|
Status LED |
|
|
CD (Carrier detect) |
The modem has detected a carrier on the phone line |
|
TR (Terminal Ready) |
The PC, PLC, or RTU is connected and ready |
|
RD (Receive Data) |
Flashes as data is recieved from the RS232 port |
|
TD (Transmit Data) |
Flashes as data is sent out of the RS232 port |
|
Power |
On when power is present |
|
General Characteristics |
|
|
Input Power |
10 - 30 VDC |
|
Input Current |
65 mA @ 24 VDC |
|
Operating Temperature |
-30º to 70ºC |
|
Storage Temperature |
-40º to 85ºC |
|
Humidity |
5% to 95% RH (non-condensing) |
|
Flammability (plastic) |
UL 94V-0 materials |
|
Telecom Certification |
FCC part 68, Industry Canada CS03-8, call SIXNET for others |
|
Electrical Safety |
UL 508, CSA C22.2/14; EN61010-1 (IEC1010) |
|
EMI emissions |
FCC part 15, ICES-003, Class A; EN55022, CE |
|
EMC immunity |
EN50082-1 (IEC801 - 2, 3, 4) |
|
Surge withstand |
IEEE-472 (ANSI C37.90) |
| Vibration | IEC68-2-6 and IEC68-2-34 |
|
Hazardous locations |
UL 1604, CSA C22.2 / 213 - M1987, (Class I, Div 2, Groups A, B, C, D) |
|
Mounting |
DIN rail or panel mount |